HEPA, ULPA Filter

[Changing the filter] Clean bench, clean bench, Dr. Filter Management HEPA Filter Validation After Replacement of Free Filter - Kyung Hee Girls' High School

알파라인랩비즈니스 2023. 4. 6. 15:22

​Hello, 

Replacement of lab, hospital, clean bench clean bench filter and

This is "Alpha Line Lab Business" specializing in cleaning and sterilization of highly pathogenic harmful bacteria, specializing in Lab Care management! ​



The work I'm going to show you this time is replacing the clean bench filter used by Kyung Hee Girls' High School.



You requested to replace the filter on the clean bench,

After changing the filter, going all the way to validation at once is the best way to maintain the performance of the equipment!



Then, let's go see the replacement of the clean bench filter of Alpha Line Lab Business, a company specializing in integrated management of experimental equipment! ​

 

Clean bench HEPA filter replacement work

 

 
 
 

Replace the HEPA Filter filter, the main filter of the clean bench.

HEPA Filter stands for High Efficiency Partialte Air Filter High Efficiency Particulate Air Filter

Particles larger than 0.3( (micrometer) such as fine dust or viruses

A high-performance purification filter that removes up to 99.99%. ​


※ When to replace the clean bench HEPA filter ※

The lifespan of the filter is estimated to be up to two years, but depending on the cleanliness of the facility, the content of the experiment, and the frequency of use

The timing of replacement may vary, but it is usually recommended to replace once a year​​​.



According to the KDCA's guidelines for bio-safety level 3 research facilities, HEPA filters can extend the replacement cycle for up to two years,

It is stated that a replacement is recommended once a year.





※ Precautions for changing filters ※

In the process of measuring the filter size, it is important to measure and manufacture the filter in the correct size without an error of 1mm.

This is because if there is an error in the filter size, harmful bacteria or viruses that are not filtered can penetrate through the gaps.

Alpha Line Lab Business is manufactured after measuring the filter size and replacing the filter regardless of manufacturer, model, model, and model year!​​



Also, in the process of opening the equipment to replace the filter, the opening method is different for each manufacturer and model of the equipment

Lack of accurate understanding and technical skills of the structure of the equipment can lead to the risk of damage during the equipment opening process!​



Alpha Line Lab Business completely completes the filter replacement work with 29 years of experimental equipment know-how.

Clean Bench Pre Filter Replacement Operation

 
 
 

The clean bench primarily filters air using a pre-filter on the air inlet face.

The clean bench is an instrument for the purpose of protecting the sample, and the introduced indoor air is used to control the air flow

It has an air structure that is filtered through a HEPA filter and then discharged in the direction of the operator​​​. ​

The pre-filter is a primary treatment filter that is in charge of the preprocessing process of the main filter and is responsible for the dust in the atmosphere,

Remove particles larger than 10 to 30 μm (micrometer) that harm the human body, such as suspended solids​​​. ​

It is recommended to replace the pre-filter once a year (operating time 800-1000h) from 6 months to 1 year​​​. ​

If you use a filter that's past the time to replace the filter, the pre-filter

The accumulation of contaminants causes loss of function and affects the air circulation process

Damage to the blower motor or contamination of the main filter may occur​​. ​

Therefore, never forget to check and replace the pre-filter periodically.

Simple Validation

 

 
 
 
 
 
 
 


There are times when you miss a case where the performance of the clean bench has deteriorated or a problem occurs.

In this case, the problem of the equipment may worsen or affect the results of the experiment, so inspection management is required​​.



Alpha Line Lab Business provides free Simple Validation when changing filters!

Simple validation is for the purpose of managing your own equipment

IQ. Installation environment, noise, illumination, horizontal, airflow, wind speed, and particles that fall under OQ

We will provide you with a report after measuring the verification​​.





※ Why Validation Equipment Verification?​

According to the guidelines of the Korea Centers for Disease Control and Prevention's 3rd and 4th grade research facilities verification technology, "Bio-safety research facilities and safety equipment are continuously maintained."

Management should be performed and re-verification should be performed periodically. Periodic re-verification is recommended once for one or two years.'

Attaching job history stickers

 

Alpha Line Lab Business will attach the work history after completing the work.

We'll record your history through Alpha Line Lab business

If the person in charge of equipment management changes, the management history is easily known,

All fieldwork for the Alpha Line Lab business is accompanied by a professional, skilled and experienced Field Manager

Operate in compliance with the safety guide manual that controls the entire operation​​​. ​



Alpha Line Lab Business is a laboratory safety integrated management company with 29 years of experience

With years of know-how and technology, we provide the best solution that always thinks of researchers.

Thank you.